YGL29C29
HYGRID™ Type YGL-C Cross Connector
Catalog ID: YGL29C29
Features: An Irreversible Compression Ground Grid Cross Connector Which Allows Adjustment Of The Compression Elements Prior To Installation, Only Six Connectors And Four Dies Are Required To Install All Combinations From 6 AWG Solid Through 500 KCMIL, UL467 Listed Acceptable For Direct Burial In Earth And Concrete, Prefilled With PENETROX Compound And Strip Sealed, Dimensions In Brackets Represent Lightning Protection Conductors, Die Index: 997 Element A, 997 Element B, Conductor Type: Run: Commercial Stranded Copper, Rebar, Ground Rod, Tools, Die Set Catalog Number, And (number Of Crimps): Element A: Y750/Y35/Y39 HYPRESS Tool, U997 Die, (1), PAT750-18V Tool, U997P Polarized Die, (1), Y45 HYPRESS Tool, U997 Die, (1), Y46 HYPRESS Tool, U997 Die, (1), Element B: Y750/Y35/Y39 HYPRESS Tool, U997 Die, (1), PAT750-18V Tool, U997P Polarized Die, (1), Y45 HYPRESS Tool, U997 Die, (1), Y46 HYPRESS Tool, U997 Die, (1), Rebar Size: #3 - #4, Ground Rod Size: 1/2 - 5/8 IN, Cable To Cable : Element A: 2 AWG Solid (0.292) - 250 KCMIL Stranded (0.575), Element B: 2 AWG Stranded (0.292) 250 KCMIL (0.575), Cable To Ground Rod: Element A: 1/2 - 5/8 IN Rod, Element B: 2 AWG Stranded (0.292) 250 KCMIL (0.575), Cable To Rebar: Element A: #3 - #4 Rebar
Product Details
General
| Application | For Direct Burial In Earth And Concrete |
| Connector Type | Tap |
| Die Index | 997 |
| EU RoHS Indicator | Yes |
| Material | Copper |
| Oxide Inhibitor Type | Penetrox E |
| Plated | N |
| Plating Type | Unplated |
| Prefilled Oxide Inhibitor | Y |
| Sub Brand | HYGROUND, HYGRID |
| Trade Name | HYGRID™ |
| Type | Taps |
| UPC | 781810220023 |
| UPC 12 Digit | 7818102200233 |
Dimensions
| Dimension - B Length fraction | 3/4 in |
| Dimension - B Length inch | 0.75 in |
| Dimension - D inch | 0.50 in |
| Dimension - L Length Overall mm | 64 mm |
| Dimension - Length BB inch | 0.75 in |
| Dimension - Length Overall inch | 2.50 in |
| Dimension - Pad Width inch | 1.66 in |
Conductor Related
| Conductor - Copper Str Size A | 2 AWG;1 AWG;1/0 ;2/0 AWG;3/0 AWG;4/0 AWG;250 kcmil |
| Conductor - Copper Str Size A Range | 2 AWG-250 kcmil |
| Conductor - Copper Str Size B | 2 AWG;1 AWG;1/0 ;2/0 AWG;3/0 AWG;4/0 AWG;250 kcmil |
| Conductor - Copper Str Size B Range | 2 AWG-250 kcmil |
| Conductor - Rebar Size A | 3 ;4 |
| Conductor - Rebar Size A Range | 3 -4 |
| Conductor - Rod Size A | 1/2 in;5/8 in |
| Conductor - Rod Size A Range | 1/2 in-5/8 in |
| Conductor Type |
|
Certifications and Compliance
| Certification - CSA Approved | Yes |
| Certification - ETL | No |
| Certification - UL Listed Direct Burial | Yes |
| Certification - UL Recognized | No |
| Certification - cULus | No |
| Industry Standard(s) |
|
| Standards - Industry Standards Met |
|
| Standards - RoHS Compliance Status | CM |
| UL Listed | Yes |
Logistics
| Carton Quantity | 10 |
| Minimum Pack Quantity | 1 |
| Pallet Quantity | 2400 |